Mitsubishi Plastics, Inc.
SUPERNYL
General Property

Article Unit SP-R SH
shrink type
Method
Thickness m 15 JIS Z 1714
Haze % 4 JIS Z 1714
Tensile Strength MPa
{Kg/mm2}
MD 280
{28}
JIS Z 1714
TD 300
{30}
Elongation % MD 120 JIS Z 1714
TD 90
Impact Strength J/piece
{Kg-cm/piece}
1.5
{15}
Puncture Test
Stick Strength N/piece
{g/piece}
6.5
{650}
diameter 0.5mm
Flex Pinhole number/0.05m2 5 Gelbo-Flex Test
23, 3000times
Shrinkage with hot water % MD 18 95, 5 min
TD 20
COF   non-Corona
/non-Corona
0.6 JIS K 7125
Oxygen Permeability fmol/(m2sPa)
{cc/(m2datm)}
40
{8}
JIS Z 1714
23, 50%RH
Water vapor Permeability g/(m2d) 100 JIS Z 0208
40, 90%RH
Wet Tension mN/m
{dyne/cm}
corona 54
{54}
JIS Z 1714
non-corona 40
{40}

The above data is NOT guaranteed.


Shrink Property Page


Copyright 2002 by Mitsubishi Plastics,Inc. All Rights Reserved.
BACK